  1. BigRedDiesel

    Throwing IDM Code...

    Here's the back story. We went to Indiana on a hunting trip, while there I parked the truck at the boat ramp. I didn't realize that the vegi pump was on with the diesel pump. Not that huge of a deal because the diesel will run at 60 PSI and vegi runs at 80 PSI. We left the ramp and was heading...
  2. BigRedDiesel

    My experience with MFI

    I just wanted to share my experience with Maryland Fuel Injection. First, yes, one of my solenoids was on backwards. Like stated in the other thread, mistakes happen we're all human. But I would like to share the rest of my experience. I called on a Monday and spoke to Greg. I asked "how soon...
  3. BigRedDiesel

    Anyone ever take an injector apart?

    I just got mine back from being rebuilt and one of the hold down brackets is on backwards. Is this something I can do myself or do you need special tools for this? I really need to get this truck running ASAP!
  4. BigRedDiesel

    Bigger injectors and cold starts?

    I've had my new injectors (238/100's) in since April 2013 and when we pulled the motor we did injectors, HPOP, studs, push rods, new tunes and a few other things I'm probably forgetting. Even since then I've noticed that the truck is absolutely miserable when it's cold. And by cold I mean air...
  5. BigRedDiesel

    Help me figure this out....

    This started on Saturday night on my way home from a 7.3 get together. I pulled into a rest area to re-attach an intercooler pipe that popped out of the boot. When I went to start the truck up this is exactly what it was doing. It has been doing it ever since. It is like this when the truck is...
  6. BigRedDiesel

    Which injectors/turbo are right for me?

    I have the follow mods listed in my signature. I just picked up ARP headstuds and want to start to collect all my stuff for when I pull the motor. I have to replace the oil pan so I figured while I was there get it all done. I was thinking about 238/80's or 238/100's. I know my modified stock...
  7. BigRedDiesel

    Harmonic balancer bolt?

    Ups has my fluidampr scheduled for delivery tomorrow morning. I was going to pull the old balancer off tonight and maybe put the Melling LPOP on. It a race against the clock at this point, but are there any tricks to getting the bolt to break loose? I just keep turning the crank....
  8. BigRedDiesel

    Checking in from South Jersey

    Just heard about the site and figured I'd stop in and introduce myself and poke around a little. The following is what I'm driving: '02, F-250, XLT, CC, 7.3PSD, 4X4, AFE Stage 2, 4" SS Full Boar Exhaust, BTS, 6.0L Trans Cooler, DP Tuner, 1.00 Non-Wastegated Turbo Exhaust Housing, Non EBPV...