  1. B

    Misfire like event under light load cold

    Still sounds like an injector Were the new ICP and IPR parts OEM or aftermarket?
  2. B

    Misfire like event under light load cold

    3924 psig maximum HPOP discharge pressure is pretty good ...... Doesn't sound like a bad HPOP or a high pressure oil system leak to me.
  3. B

    Just when you think you seen it all

    Please post that pic when you get it out!! And tell us if it is magnetic or not.
  4. B

    2006 Very Low Base Oil Pressure

    Can you answer CTCDEEZUL's questions?
  5. B

    ICP issue ?

    The oil pressure sensor ONLY goes to the dash gauge. It is not even connected to the PCM. It plays no part in any engine operational strategy.
  6. B

    ICP issue ?

    Not sure why the ICP sensor would cause raw fuel to be dumped, but sounds like it needs to be replaced (or the connector/pigtail needs replacing).
  7. B

    ICP issue ?

    The white exhaust smoke sounds like an injector dumping fuel. You can do a lot of damage to the engine if you drive it without addressing that issue. The ICP might be an issue also, but the injector issue is a priority to resolve.
  8. B

    Anything new?

    IMO many/most of the high flow oil coolers do not cool as well as OEM
  9. B

    05 fog lights won't turn on

    Sorry it so long to post these
  10. B

    05 fog lights won't turn on

    The best thing to do if you STRONGLY suspect the relay is to just cut the wires to/from that particular relay and add one to the wiring external to the CJB. If I have some time, I will try to look up the connector number and wire color.
  11. B

    05 fog lights won't turn on

    That relay, along with a few others, is built into the CJB or Central Junction Box (fuse panel under the dash on driver's side): Fog Lamp Relay Fuel Pump Relay Horn Relay Trailer Tow Parking Lamp Relay Heated Mirror Relay It is considered a non-serviceable item and, if bad, Ford will recommend...
  12. B

    05 fog lights won't turn on

    Sounds more like a relay issue, but please post the solution when you find it!
  13. B

    05 fog lights won't turn on

    The ground is the G100 (black wire). Firewall drivers side IIRC. Power is supplied through the CJB relay connector C270h (TN/OG wire). You can pull the fog lamp connectors C152 and C162 and turn the fog lamp switch on ..... see if there is voltage between the power wire (TN/OG) and the...
  14. B

    05 fog lights won't turn on

    Check the grounds.
  15. B

    05 f250 hard starting when warm

    It is likely to be a starter issue, but that said - even new batteries can be bad. Seen it too many times. Just checking static voltage isn't a good way to be sure of battery health. A load test is best. If you are watching the ICP value when cranking, and your cranking rpms are that slow...
  16. B

    2005 CCSB fuel tank question

    You don't have to pull the tank. You can raise the bed. Remove the bed bolts up by the cab. Just loosen the ones near the tailgate. You may need an impact to get the bolts lose, but if you have one, the job is easier this way. After that, you can tilt the bed up w/ a jack. Support it w/...
  17. B

    Help blue smoke issue

    That much fuel in the oil and your turbo bearings suffer .....
  18. B

    Help blue smoke issue

    I agree w/ Zeb - the OP didn't say anything about hard start when cold or rough running once started. Stiction will usually cause these issues as well as the white smoke. For the description, the smoke / unburned fuel is pretty significant. From that, IMO it is a full blown injector issue.
  19. B

    6.0 starts and dies

    Post #11 is where he needed to go next. Maybe that can help you ....
  20. B

    Help blue smoke issue

    +1 - not an oil or stiction issue.